Research

994

Receipt of test results online

To ensure full transparency, we make the results of the research available on our website under the 'Research' tab. Furthermore, each report contains a unique order number and password. With these, you can verify the data on the www.analizabialek.com in the "Online results" section. Simply enter the information provided to confirm that the product meets the declared specification. For example, the reports show the purity of the peptides, which is key to their effectiveness.

TIRZEPIC GLP-1 + GIP study

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration after comparison with the reference chromatogram is 5,45mg.

Heavy metals test Methylene blue 30ml

The ICP-MS method, which has high precision and sensitivity, was used for methylene blue analysis. The tests were carried out in a laboratory accredited according to AB 1334 (range available at www.pca.gov.pl), as well as S-406 (see our website for details). These include the determination of cadmium, lead, mercury and arsenic with a limit of determination of 0.01 mg/kg, so that trace amounts of heavy metals can be detected. As a result, results were obtained in accordance with accredited procedures.

Melanotan 2 study

The test sample was applied at 2ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared as a peak of the substance sought. Its concentration, when compared with the standard chromatogram, is 10.02mg.

BPC study 157

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration when compared to the reference chromatogram is 10.34mg.

Epithalon study

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration, after comparison with the reference chromatogram, is 10.86mg.

N-Acetyl Semax study

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration, when compared with the reference chromatogram, is 51.83mg.

GHK-CU study

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration, when compared with the reference chromatogram, is 52.14mg.

TB500 test

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% trifluoroacetic acid appeared peak of the substance sought. Its concentration, after comparison with the reference chromatogram, is 9.32mg.

Methylene Blue study

The test sample was applied at 3ul to a Thermo Scientific BioBasic 8 column. During the course of the analysis by linear gradient in solutions of H20 and Acetonitrile with 0.1% acid trifuluoroacetic acid appeared in spades of the substance sought. Its concentration when compared to standard chromatogram is 10.48mg/ml.

Precision Analytical Reagents

At EmpireLab, we supply chemical reagents, such as peptides, that meet rigorous laboratory standards. Therefore, each batch of products undergoes thorough testing in independent laboratories. In particular, the liquid chromatography method (HPLC-UV) is used, which ensures precise determination of the composition and purity of the substance. This provides us with detailed reports and the results confirm the reliability of our products.

Commitment to Quality

EmpireLab is committed to quality and transparency. That is why our reagents are tested without compromise and the testing process is based on accredited standards. We invite you to check out the reports that show how we ensure our products comply with scientific requirements.